ʻAoʻao hae

OM3 50/125 GYXTW waho Optical Fiber Cable Central Loose waho Cable

ʻO ka wehewehe pōkole:

ʻO GYXTW Fiber Optic Cable e hoʻopaʻa i ka fiber optical 250μm i loko o kahi paipu manuahi i hoʻopiha ʻia me ka pūhui wai.

Hoʻohana nui ʻia ka GYXTW Fiber Optic Cable no ke kamaʻilio lōʻihi a me ke kamaʻilio ma waena o ke keʻena, ʻo ia ka mea i hoʻohana nui ʻia i ka honua.

ʻO ka GYXTW Fiber Optic Cable ka Unitube Light Armored fiber optic cable. He ʻano ia o ka fiber optic uwea i hoʻohana nui ʻia i ka noi ʻana o waho.

ʻO ka lālā like me ka uea kila, ka mea hoʻopihapiha pale i ka paipu fiber steel tape i hoʻopaʻa ʻia.

Hana maikaʻi loa ka mīkini a me ke kaiapuni.

ʻO ka hoʻolālā paʻa, hiki ke hoʻokomo maʻalahi a hoʻohana maʻalahi.


Huahana Huahana

Huahana Huahana

GYXTW Fiber Optic Cable Mechanical Character:

Helu fiber Anawaena uwea Kaumaha
1~12 8.0mm+-0.3mm 70kg/km
7.0mm+-0.1mm 50kg/km
Kaulana wela -40°C+70°C
ʻUmi Piʻo min (mm) Wā lōʻihi 10D
Min PiʻoUku (mm) wā pōkole 20D
ʻAe ʻia ka ikaika ʻuʻuku (N) Wā lōʻihi 1200
ʻAe ʻia ka ikaika ʻuʻuku (N) wā pōkole 1500
Hana wela -40°C+70°C
Mahana hoʻokomo -20°C+60°C
Ka mahana mālama -40°C+70°C

ʻO ke ʻano fiber:

Kaila fiber Unite MM OM3-300
kūlana nm 850/1300
hōʻemi dB/km ≤3.0/1.0
    ----
Hoʻopuehu 1550nm Ps/(nm*km) Hoʻopuehu
  1625nm Ps/(nm*km)  
Kaʻeleʻele 850nm MHZ.KM Kaʻeleʻele
  1300nm MHZ.KM  
Ka lōʻihi o ka hoʻopuehu Zero nm ≧ 1295, ≤1320
Kolo hoʻopuehu ʻana nm ----
PMD Kiʻekiʻe o kēlā me kēia Fiber   ≤0.11
Waiwai Link Hoʻolālā PMD Ps(nm2*km) ----
Ka lōʻihi o ka hawewe λc nm ----
Ka lōʻihi o ka nalu ʻoki uwea λcc nm ----
MFD 1310nm um ----
  1550nm um ----
Puka helu (NA)   0.200+/-0.015
Step(mean of bidirectional ana ana) dB ≤0.10
ʻAʻole pololei ma luna o ka lōʻihi a me ke kiko dB ≤0.10

kala kala:

1 2 3 4 5 6
Polū Alani ʻōmaʻomaʻo Palaunu Hinahina Keʻokeʻo
7 8 9 10 11 12
ʻulaʻula ʻeleʻele Melemele Violet ʻulaʻula Aqua
OM3 5025 GYXTW Kūwaho Optic4

He aha ke kelepona GYXTW?

ʻO GYXTW fiber optic cable, nā fibers 250μm, ua hoʻonoho ʻia i loko o kahi paipu manuahi i hana ʻia me ka plastic modulus kiʻekiʻe.

Hoʻopihaʻia nā paipu me kahi mea hoʻopihapiha hoʻopihapiha wai.

Hoʻopili ʻia ka paipu me kahi papa o PSP me ka lōʻihi.

Hoʻopili ʻia ma waena o ka PSP a me ka mea hoʻopaʻa wai paʻa i mea e hoʻopaʻa paʻa a paʻa i ka wai.

Hoʻokomo ʻia ʻelua uea kila like ma nā ʻaoʻao ʻelua o ka lipine kila.

Hoʻopau ʻia ke kaula me kahi puʻu polyethylene (PE).

Ua hoʻomohala ʻia ke kaula fiber OM3 e like me nā kūlana 10Gbit hou loa a hiki i ka lawe ʻana i ka ʻikepili ma kahi mamao a hiki i ka max 300 m ma 850 nm. Ma muli o kāna mau hiʻohiʻona maikaʻi loa, ʻē aʻe ma mua o nā fibers 600/1200 nm maʻamau, ua pili ka OM3 fiber optic cable no nā pilina kuamoʻo e pili ana i kahi ʻenehana multi-mode kumu kūʻai a hiki i 10Gbit.

Kūkulu ʻia:

OM3 5025 GYXTW Kūwaho Optic3

Nā hiʻohiʻona:

ʻO ka lālā like me ka uea kila, ka mea hoʻopihapiha pale i ka paipu fiber steel tape i hoʻopaʻa ʻia.

Hana maikaʻi loa ka mīkini a me ke kaiapuni.

ʻO ka hoʻolālā paʻa, hiki ke hoʻokomo maʻalahi a hoʻohana maʻalahi.

Loaʻa nā koho fiber ʻē aʻe: Single mode (G652D, G657A, G657B) a me Multimode (OM1, Om2, Om3, OM4, OM5)

Helu fiber: 2fo ~ 12fo

Ke koho anawaena: 6.0mm, 7.0mm (ex-work), 8.0mm

Noi:

+ Hoʻokomo ʻia i ka hoʻohele ʻana i waho.

+ He kūpono no ka aerial, pipeline laying method.

+ ʻO ka lōʻihi lōʻihi a me ke kamaʻilio pūnaewele wahi.

OM3 5025 GYXTW Kūwaho Optic5

Hoʻopili:

OM3 5025 GYXTW Kūwaho Optic1

  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou