ʻAoʻao-1 o ka hae KCO-Fiver-MTP-MPO-QSFP

400G QSFP

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

Hoʻohui ʻia ka Module Transceiver Optical 400GBASE-SR8 QSFP-DD i ka 2 × 200G-SR4 a me 8 × 50G-S

- ʻAno QSFP-DD hiki ke hoʻopili ʻia me ka wela

- Kākoʻo i ka wikiwiki bit aggregate 400Gb/s

- A hiki i ka 53.125Gbps ka wikiwiki o ka ʻikepili no kēlā me kēia kahawai

- ʻO ka lōʻihi loulou kiʻekiʻe loa he 70m ma OM3 a me 100m ma OM4

- Kahi hoʻohui MPO

- Pae mahana o ka hihia: 0 ~ +70

- Ka hoʻopuehu ʻana o ka mana: <10W

- Hoʻolako mana 3.3V hoʻokahi

- Ua hōʻoia ʻia ke kūlike ma Arista/NVIDIA/Cisco RoCE Networking

- Bandwidth kiʻekiʻe

- Latency Haʻahaʻa

- Kūlike me QSFP-DD MSA

- Kūlike me IEEE 802.3cd

- Hoʻopiʻi RoHS

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

Hoʻohālikelike ʻia me 400GBASE-FR QSFP-DD 4 * 100G PAM4 Optical Transceiver Module 1310nm 2Km DOM MPO-12/APC Fiber Optic Equipment

- Kūlike me ka QSFP-DD MSA

- Mea hoʻohui MPO-12 me ka ʻaoʻao hope 8° angled

- Ka hoʻohana ʻana i ka mana <11 W

- Mahana hihia hana 0 a 70 ºC

- Hoʻokele pūnaewele CMIS 4.0

- ʻAno Breakout • 4x 100GBASE-FR1 kūlike 53.125GBd PAM4 • 100GAUI-2 kūlike 2x 26.5625 GBd PAM4

- ʻAno Hoʻohuihui • 400GBASE-FR4 kūlike 4x 53.125GBd PAM4 • 400GAUI-8 kūlike 8x 26.5625 GBd PAM4

KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Optical Transceiver Module, Breakout i 4 x 100G-DR

KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Optical Transceiver Module, Breakout i 4 x 100G-DR

- Kūlike me QSFP-DD MSA

- ʻEhā mau Alanui Optical Parallel 1310nm

- Kūlike nā kikoʻī IEEE 802.3bs 400GBASE-DR4

- Kūlike me ke Koi RoHS

- A hiki i ka 500m Hoʻouna ma SMF me FEC

- 8×53. 125Gb/s Uila Hoʻohui (400GAUI-8)

- Ka helu ʻikepili 4* 106.25Gbps (PAM4) Optical Interface

- Pae Mahana o ka Hihia: 0 a 70.C

- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa he 10W

- Mea Hoʻohui MPO-12

- Nā Hana Diagnostic Kikohoʻe i kūkulu ʻia

KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Optical Transceiver Module

KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Optical Transceiver Module

- Kūlike me QSFP-DD MSA

- 4 mau ala CWDM MUX/DEMUX hoʻolālā

- Mea hoʻohui LC Duplex

- A hiki i ka hoʻoili ʻana he 10km ma ka fiber mode hoʻokahi (SMF) me FEC

- 8 × 53.125Gb/s uila (400GAUI- 8)

- Ka helu ʻikepili 106.25Gbps (PAM4) no kēlā me kēia kahawai

- Pae mahana o ka hihia: 0 ~ +70

- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa 9W

- Hoʻopiʻi RoHS

400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Breakout i 4 x 100G-SR1.2

400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Breakout i 4 x 100G-SR1.2

- QSFP-DD MSA

- 8x 53.125Gb/s Uila Interface (400GAUI-8) Kūpono

- A hiki i ka 150m OM5 MMF hoʻoili

- Mea Hoʻohui Optical MPO-12

- Hoʻokō i ka RoHS

- Hoʻolako Mana 3.3 V hoʻokahi

- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa 12W

- Mahana o ka hihia hana: 0°C a i 70°C