KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC
Hoʻohui ʻia ka Module Transceiver Optical 400GBASE-SR8 QSFP-DD i ka 2 × 200G-SR4 a me 8 × 50G-S
- ʻAno QSFP-DD hiki ke hoʻopili ʻia me ka wela
- Kākoʻo i ka wikiwiki bit aggregate 400Gb/s
- A hiki i ka 53.125Gbps ka wikiwiki o ka ʻikepili no kēlā me kēia kahawai
- ʻO ka lōʻihi loulou kiʻekiʻe loa he 70m ma OM3 a me 100m ma OM4
- Kahi hoʻohui MPO
- Pae mahana o ka hihia: 0 ~ +70℃
- Ka hoʻopuehu ʻana o ka mana: <10W
- Hoʻolako mana 3.3V hoʻokahi
- Ua hōʻoia ʻia ke kūlike ma Arista/NVIDIA/Cisco RoCE Networking
- Bandwidth kiʻekiʻe
- Latency Haʻahaʻa
- Kūlike me QSFP-DD MSA
- Kūlike me IEEE 802.3cd
- Hoʻopiʻi RoHS
KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S
Hoʻohālikelike ʻia me 400GBASE-FR QSFP-DD 4 * 100G PAM4 Optical Transceiver Module 1310nm 2Km DOM MPO-12/APC Fiber Optic Equipment
- Kūlike me ka QSFP-DD MSA
- Mea hoʻohui MPO-12 me ka ʻaoʻao hope 8° angled
- Ka hoʻohana ʻana i ka mana <11 W
- Mahana hihia hana 0 a 70 ºC
- Hoʻokele pūnaewele CMIS 4.0
- ʻAno Breakout • 4x 100GBASE-FR1 kūlike 53.125GBd PAM4 • 100GAUI-2 kūlike 2x 26.5625 GBd PAM4
- ʻAno Hoʻohuihui • 400GBASE-FR4 kūlike 4x 53.125GBd PAM4 • 400GAUI-8 kūlike 8x 26.5625 GBd PAM4
KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Optical Transceiver Module, Breakout i 4 x 100G-DR
- Kūlike me QSFP-DD MSA
- ʻEhā mau Alanui Optical Parallel 1310nm
- Kūlike nā kikoʻī IEEE 802.3bs 400GBASE-DR4
- Kūlike me ke Koi RoHS
- A hiki i ka 500m Hoʻouna ma SMF me FEC
- 8×53. 125Gb/s Uila Hoʻohui (400GAUI-8)
- Ka helu ʻikepili 4* 106.25Gbps (PAM4) Optical Interface
- Pae Mahana o ka Hihia: 0 a 70.C
- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa he 10W
- Mea Hoʻohui MPO-12
- Nā Hana Diagnostic Kikohoʻe i kūkulu ʻia
KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Optical Transceiver Module
- Kūlike me QSFP-DD MSA
- 4 mau ala CWDM MUX/DEMUX hoʻolālā
- Mea hoʻohui LC Duplex
- A hiki i ka hoʻoili ʻana he 10km ma ka fiber mode hoʻokahi (SMF) me FEC
- 8 × 53.125Gb/s uila (400GAUI- 8)
- Ka helu ʻikepili 106.25Gbps (PAM4) no kēlā me kēia kahawai
- Pae mahana o ka hihia: 0 ~ +70℃
- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa 9W
- Hoʻopiʻi RoHS
400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Optical Transceiver Module, Breakout i 4 x 100G-SR1.2
- QSFP-DD MSA
- 8x 53.125Gb/s Uila Interface (400GAUI-8) Kūpono
- A hiki i ka 150m OM5 MMF hoʻoili
- Mea Hoʻohui Optical MPO-12
- Hoʻokō i ka RoHS
- Hoʻolako Mana 3.3 V hoʻokahi
- Ka hoʻohana ʻana i ka mana kiʻekiʻe loa 12W
- Mahana o ka hihia hana: 0°C a i 70°C