ʻAoʻao-1 o ka hae KCO-Fiver-MTP-MPO-QSFP

ʻO ke kaula ʻāpana fiber optic OM3-150 OM3-300 8cores MTP i LC / MPO i LC fanout

Wehewehe Pōkole:

- Mea Hoʻohui 1: MPO-8, MTP-8

- Mea Hoʻohui 2: LC/UPC MM

- ʻAno fiber: Multimode OM3-150 a i ʻole Multimode OM3-300

- Polarity: ʻAno B (koho: ʻAno A, ʻAno C)

- Ka lōʻihi o ka Fanout: 0.3m (30cm)

- Noi: hoʻohana no ka module MPO MTP. pahu

- Ka manawa alakaʻi: 2 lā

- MOQ: 1pc

 

 


Nā kikoʻī huahana

Nā Lepili Huahana

He aha ke kaula hoʻopili MPO a LC fant-out?

+ MPO a i LC / MTP a i LC fiber optic fan-out patch cord he hui fiber optic i hoʻohana ʻia e hoʻopili i nā pilina multi-fiber kiʻekiʻe-density i nā awa fiber hoʻokahi pākahi.

+ Loaʻa ia ma 8fiber, 12fiber a i ʻole 24 fibers. Hoʻohana maʻamau e hoʻokomo i loko o ka pahu module MTP MPO no ka panela patch density kiʻekiʻe.

+ He mea nui kēia mau kaula no ka hoʻopili ʻana i nā transceivers 40G/100G/400G wikiwiki (e like me QSFP+) i nā lako 10G SFP+ i loaʻa i nā kikowaena ʻikepili.

+ Helu Fiber: ʻO nā hoʻonohonoho maʻamau e komo pū me 8-fiber (no 40G QSFP a i 4x10G LC), 12-fiber (a i 6xLC duplex), a i ʻole 24-fiber (a i 12xLC duplex)

+ ʻAno Fiber: Multimode OM3, hoʻohana ʻia no nā loulou kikowaena ʻikepili pōkole.

+ Kāne: Hiki i nā mea hoʻohui MPO ke kāne (me nā pine).

+ Polarity: Hoʻohana pinepine nā polokalamu maʻamau 40G/100G i ka polarity Type B (Rollover) e hōʻoia i ka hoʻohālikelike kūpono o ka hoʻouna-a-loaʻa (Tx a Rx).

 

Nā noi

+ 40G/100G a i 10G/25G Neʻe ʻana

+ Hoʻohui pololei ʻana o ka hāmeʻa-i-ka-kuʻina

+ Ke Alanui ʻana mai ke Kuamoʻo a i ka Mea Hana: Ma nā kikowaena ʻikepili, holo nā kaula kumu MPO kiʻekiʻe (e laʻa, 24 a i ʻole 144 mau olonā) ma waena o nā racks ma ke ʻano he iwi kuamoʻo. Hana nā kaula Fanout ma ke ʻano he "alahaka," e hoʻokaʻawale ana i kēia mau kumu multi-fiber i nā mea hoʻohui LC pākahi e hoʻopili pololei i nā awa lako o ka mea hoʻohana hope.

+ Hoʻopili ʻana i ka Density Kiʻekiʻe: Hoʻohana ʻia kēia mau kaula i loko o nā pā fiber e hoʻohui i nā awa LC duplex he nui i loko o kahi interface MPO hoʻokahi, e hoʻonui nui ana i ka nui o ke awa. No ka laʻana, ʻo kahi 12-fiber MPO a i 6x LC duplex fanout e ʻae i ʻeono mau loulou duplex kaʻawale e hoʻokele ʻia ma ke ʻano he ʻāpana kaula hoʻokahi.

 

 

Nā kikoʻī

ʻAno

ʻAno Hoʻokahi

ʻAno Hoʻokahi

ʻAno Multi

(APC Polani)

(UPC Polani)

(PC Polani)

Helu o ka fiber

8, 12, 24 a pēlā aku.

8, 12, 24 a pēlā aku.

8, 12, 24 a pēlā aku.

ʻAno Fiber

G652D, G657A1 a pēlā aku.

G652D, G657A1 a pēlā aku.

OM1, OM2, OM3, OM4, a pēlā aku.

Pohō Hoʻokomo Nui Loa

ʻElite

Kūlana Maʻamau

ʻElite

Kūlana Maʻamau

ʻElite

Kūlana Maʻamau

Pohō haʻahaʻa

Pohō haʻahaʻa

Pohō haʻahaʻa

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.60dB

Hoʻihoʻi Pohō

≥60 dB

≥60 dB

NA

Ka paʻa

≥500 mau manawa

≥500 mau manawa

≥500 mau manawa

Mahana Hana

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

Ka lōʻihi o ka nalu hoʻāʻo

1310nm

1310nm

1310nm

Hoʻāʻo hoʻokomo-huki

1000 manawa <0.5 dB

Hoʻololi

0.5 dB

Ka ikaika anti-tensile

15kgf

MTP-MPO a i LC fanout fiber optic patch cable

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou