ʻAoʻao-1 o ka hae KCO-Fiver-MTP-MPO-QSFP

MTP/MPO i FC OM4 16fo Fiber Optic Patch Cable

Wehewehe Pōkole:

- Hoʻopau mua ʻia e ka hale hana a hōʻoia ʻia e hāʻawi ana i ka hana optical kiʻekiʻe loa.

- Ua hoʻāʻo ʻia kēlā me kēia kaula 100% no ka pohō hoʻokomo haʻahaʻa a me ka noʻonoʻo hope

- Ua mākaukau nā kaula no ka hoʻolaha ʻana i ka wā e hōʻea ai

- Hoʻokomo ʻia me ka pale a me nā lima huki no ke kūpaʻa ʻana i ka haki


Nā kikoʻī huahana

Nā Lepili Huahana

Nā wehewehe

+ ʻO ke kaula ʻāpana MTP/MPO, he kaula fiber optic i hoʻopau ʻia me nā mea hoʻohui MTP/MPO ma kekahi ʻaoʻao a me ka mea hoʻohui MTP/MPO ma kekahi ʻaoʻao.

+ ʻO ke kaula nui he 3.0mm LSZH Poepoe maʻamau.

+ Hiki iā mākou ke hana i ka pohō hoʻokomo ma ke ʻano Standard a me ke ʻano Elite.

+ Hiki iā mākou ke hāʻawi aku i nā kaula ʻāpana fiber optical mode Single a me Multimode MTP, nā hoʻolālā maʻamau o nā ʻākoakoa kaula fiber optic MTP, mode Single, Multimode OM1, OM2, OM3, OM4, OM5.

+ Loaʻa ia i 16 mau ʻāpana (a i ʻole 8 mau ʻāpana, 12 mau ʻāpana, 24 mau ʻāpana, 48 ʻāpana, a pēlā aku).

+ Ua hoʻolālā ʻia nā kaula ʻāpana MTP/MPO no nā noi mānoanoa kiʻekiʻe e koi ana i ka hana kiʻekiʻe a me ka hoʻonohonoho wikiwiki. Hāʻawi nā kaula harness i kahi hoʻololi mai nā kaula multi-fibers i nā fibers pākahi a i ʻole nā ​​​​mea hoʻohui duplex.

+ Loaʻa ka mea hoʻohui MPO/MTP wahine a me kāne a he mau pine ko ka mea hoʻohui ʻano kāne.

MTP-MPO a i FC OM3 16fo Fiber Optic Patch Cable

E pili ana i nā kaula multimode

+ Loaʻa i ke kaula fiber optic multimode kahi ʻiwi diametral nui e hiki ai i nā ʻano kukui he nui ke hoʻolaha. Ma muli o kēia, piʻi ka nui o nā ʻōlinolino kukui i hana ʻia i ka wā e hele ai ke kukui ma o ke kumu, e hana ana i ka hiki ke hele hou aku ka ʻikepili i kahi manawa i hāʻawi ʻia. Ma muli o ke kiʻekiʻe o ka hoʻolaha ʻana a me ka attenuation rate me kēia ʻano fiber, ua hoʻemi ʻia ke ʻano o ka hōʻailona ma nā mamao lōʻihi. Hoʻohana pinepine ʻia kēia noi no nā mamao pōkole, ʻikepili a me nā noi leo/wikiō ma LANs.

+ Ua wehewehe ʻia nā olonā multimode e ko lākou anawaena core a me ke cladding. ʻO ka maʻamau, ʻo ke anawaena o ka olonā multi-mode he 50/125 µm a i ʻole 62.5/125 µm. I kēia manawa, ʻehā ʻano o nā olonā multi-mode: OM1, OM2, OM3, OM4 a me OM5.

+ ʻO ke kaula OM1 maʻamau e hele mai me kahi ʻaʻahu ʻalani a he 62.5 micrometers (µm) ka nui o ke kikowaena. Hiki iā ia ke kākoʻo i ka 10 Gigabit Ethernet ma ka lōʻihi a hiki i 33 mika. Hoʻohana pinepine ʻia ia no nā noi 100 Megabit Ethernet.

+ Loaʻa iā OM2 kahi waihoʻoluʻu ʻalani i manaʻo ʻia. ʻO ka nui o kona kikowaena he 50µm ma kahi o 62.5µm. Kākoʻo ia i ka 10 Gigabit Ethernet ma ka lōʻihi a hiki i 82 mika akā ʻoi aku ka hoʻohana pinepine ʻia no nā noi 1 Gigabit Ethernet.

+ Loaʻa iā OM3 kahi waihoʻoluʻu wai i manaʻo ʻia. E like me OM2, ʻo kona nui kumu he 50µm. Kākoʻo ʻo OM3 i ka 10 Gigabit Ethernet ma nā lōʻihi a hiki i 300 mika. Eia kekahi, hiki iā OM3 ke kākoʻo i ka 40 Gigabit a me 100 Gigabit Ethernet a hiki i 100 mika. ʻO 10 Gigabit Ethernet kāna hoʻohana maʻamau.

+ Loaʻa iā OM4 kahi waihoʻoluʻu ʻaʻahu i manaʻo ʻia he aqua. He hoʻomaikaʻi hou aʻe ia i ka OM3. Hoʻohana pū ia i kahi ʻiʻo 50µm akā kākoʻo ia i ka 10 Gigabit Ethernet ma nā lōʻihi a hiki i 550 mika a kākoʻo ia i ka 100 Gigabit Ethernet ma nā lōʻihi a hiki i 150 mika.

Nā noi

+ Hoʻohui kikowaena ʻikepili

+ Hoʻopau ʻana i ka hopena poʻo i kahi "iwi kuamoʻo" o ka fiber

+ Hoʻopau ʻana i nā ʻōnaehana rack fiber

+ Metro

+ Hoʻohui Kūʻē ʻo High-Density

+ Nā Pūnaewele Kelepona

+ Nā Pūnaewele Broadband/CATV/LAN/WAN

+ Nā Keʻena Hoʻāʻo

MTP-MPO a i FC OM3 16fo Fiber Optic Patch Cable

Nā kikoʻī

ʻAno

ʻAno Hoʻokahi

ʻAno Hoʻokahi

Multimode

(APC Polani)

(UPC Polani)

(PC Polani)

Helu o ka fiber

8, 12, 24 a pēlā aku.

8, 12, 24 a pēlā aku.

8, 12, 24 a pēlā aku.

ʻAno Fiber

G652D, G657A1 a me nā mea ʻē aʻe.

G652D, G657A1 a me nā mea ʻē aʻe.

ʻOM1, OM2, OM3, OM4, OM5, a pēlā aku.

Pohō Hoʻokomo Nui Loa

ʻElite

Kūlana Maʻamau

ʻElite

Kūlana Maʻamau

ʻElite

Kūlana Maʻamau

Pohō haʻahaʻa

Pohō haʻahaʻa

Pohō haʻahaʻa

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.75dB

≤0.35 dB

≤0.60dB

Hoʻihoʻi Pohō

≥60 dB

≥60 dB

NA

Ka paʻa

≥500 mau manawa

≥500 mau manawa

≥500 mau manawa

Mahana Hana

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

Ka lōʻihi o ka nalu hoʻāʻo

1310nm

1310nm

1310nm

Hoʻāʻo hoʻokomo-huki

1000 manawa≤0.5 dB

Hoʻololi

≤0.5 dB

ʻAno kaula ʻāpana MTP MPO ABC

MTP-MPO a i FC OM3 16fo Fiber Optic Patch Cable

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou