ʻAoʻao hae

800GBASE 2xSR4/SR8 OSFP Finned Top PAM4 850nm 50m DOM Dual MPO-12/APC MMF Optical Transceiver Module

ʻO ka wehewehe pōkole:

- Pili ʻo Cisco OSFP-800G-VR8

- NVIDIA/Mellanox MMA4Z00-NS kūpono

- Nā Pūnaewele Arista OSFP-800G-2VSR4 kūpono

- Hui Pūnaewele ʻo Juniper OSFP-2X400G-VR4-P Pili

- H3C OSFP-800G-VR8-MM850-DMPO Pili

-ʻO nā mea ʻē aʻe


Huahana Huahana

Huahana Huahana

wehewehe

+ ʻO ka KCO-OSFP-800G-SR8 800Gbase kiʻekiʻe ka māmā fiber optic module he kiʻekiʻe-bandwidth transceiver no ka pōkole (hiki i ka 100m) multimode fiber noi, hoʻohana nui ʻia i nā kikowaena data, high-performance computing (HPC), a me Artificial Intelligence (AI) kaiapuni no nā noi e koi ana i nā pili haʻahaʻa.

+ Hiki iā ia ke hoʻololi i ka hoʻololi, hoʻololi i ka server, a me nā pilina pili pūnaewele i loko o kahi hoʻolālā pūnaewele 51.2T, e kākoʻo ana i nā protocol Ethernet a me InfiniBand.

+ Ua hoʻolālā ʻia ka module transceiver optical 800GBASE-SR8 OSFP no 800GBASE Ethernet throughput a hiki i ka 50m link long over OM4 multimode fiber (MMF) me ka hoʻohana ʻana i ka nalu o 850nm ma o nā mea hoʻohui MTP/MPO-12 APC ʻelua.

+ Hoʻopili kēia transceiver i nā kūlana IEEE P802.3ck, OSFP MSA.

+ ʻO ka nānā ʻana i nā diagnostics digital i kūkulu ʻia (DDM) hiki ke komo i nā ʻāpana hana manawa maoli.

+ Hoʻohana ʻia ka transceiver māhoe ʻo OSFP finned-top transceiver i nā hoʻololi hoʻoluʻu ea Ethernet.

+ Hōʻike ʻia me ka haʻahaʻa haʻahaʻa, ka mana haʻahaʻa, a me ka hilinaʻi, hiki iā ia ke hoʻopili i luna i nā kiʻi kiʻi spine-lau no nā noi hoʻololi-i-hoʻololi, i lalo no nā loulou hoʻololi top-of-rack i nā mea hoʻopili pūnaewele Ethernet, a / a i nā BlueField-3 DPUs i nā kikowaena helu a me nā subsystem mālama.

+ ʻO ia ka hopena kūpono no ka HPC computing, AI, a me nā kikowaena data cloud.

ʻano hana

+Hoʻolālā ʻAwa Mālua:Hōʻike ka inoa "SR8" i nā alana 8 o ka modulation 100G-PAM4, i hoʻokaʻawale pinepine ʻia i ʻelua mau kahawai 400G kūʻokoʻa (2x400G) i loko o hoʻokahi module OSFP, me ka hoʻohana ʻana i ʻelua mau mea hoʻohui MPO/MTP-12.

+Multimode Fiber:Hoʻohana ia i nā VCSEL lōʻihi hawewe 850nm a me ka fiber multimode (MMF) no ka hoʻouna ʻana i ka ʻikepili kiʻekiʻe ma nā mamao pōkole.

+Hiki ke hoʻopili wela:ʻO ka OSFP form factor he wela-pluggable, hiki ke maʻalahi i ka hoʻokomo a me ka mālamaʻana me ka paniʻoleʻana i nā lako pūnaewele.

Hiʻona

+ Nā hoʻāʻo ʻana no ka hana ʻoi aku ka maikaʻi, ka maikaʻi, a me ka hilinaʻi

+ ʻO Marvell 6nm DSP Chip i kūkulu ʻia, Max. Hoʻohana mana 16W

+ Kiʻekiʻe-wikiwiki Hoʻohui pili i IEEE 802.3ck

+ Hoʻopili ʻia ʻo OSFP MSA Hoʻohui wela

+ Kākoʻo iā 2x 400G a i ʻole 4x 200G Breakout no ke kiʻekiʻe kiʻekiʻe o ke awa.

+ 8x 106.25G PAM4 Hoʻomaha 8x 100GAUI-8 C2M Kikowaena Uila

+ No ka Bandwidth kiʻekiʻe ma Hyperscale Data Centers a me Cloud Infrastructure

+ Papa 1M Laser Palekana a me RoHS Compliant

+ Kikohoʻe Optical Mākaʻikaʻi hiki no ka ikaika Diagnostic hiki

Nā kikoʻī

Pili ʻo Cisco

OSFP-800G-VR8

Brand

 KCO

Kumu Kumu

ʻO luna kiʻekiʻe ʻo OSFP ʻelua awa

Ka helu ʻikepili kiʻekiʻe

 850Gbps (8x 106.25Gbps)

Loʻihi nalu

 850nm

Ka lōʻihi o ke kelepona

 30m@OM3 / 50m@OM4

Mea hoʻohuiʻAno

ʻElua MTP/MPO-12 APC

ʻO ka fiberʻAno

 MMF

ʻAno hoʻouna

VCSEL

ʻAno Loaʻa

PIN

TX Mana

-4.6~4dBm

Mana Loaʻa liʻiliʻi

-6.4dBm

Ka Mana Mana

1.8dB

Loaʻa ʻOi aku ka ukana

4dBm

Hoʻohana mana ʻoi loa 

16W

Laki hoopau

2.5dB

DDM/DOM

Kākoʻo ʻia

Palena Mahana Kalepa

0 a 70°C

Modulation (Uila)8x100G-PAM4

Hoʻololi (Optical)

4x100G-PAM4 pālua

CDR (Kaka a me ka hoʻihoʻi ʻikepili)

TX & RX CDR i kūkulu ʻia

FEC i kūkulu ʻia

ʻAʻole

Nā Kūlana

OSFP MSA, CMIS 5.0, IEEE 802.3db, IEEE 802.3ck

Palapala hōʻoia

5 Makahiki

Nā noi

+Nā hui kikowaena ʻikepili:Hoʻohui i nā hoʻololi kiʻekiʻe i loko o nā hale kiʻi spine-leaf a hiki ke hoʻololi i nā loulou top-of-rack switch-to-server no ka neʻe wikiwiki ʻana o ka ʻikepili i loko o ke kikowaena ʻikepili.

+Nā Pūʻulu AI/ML:Hāʻawi i ka bandwidth kiʻekiʻe e pono ai a me ka latency haʻahaʻa e hoʻopili i nā kikowaena helu, DPU, a me nā mea hoʻopili pūnaewele ma AI a me nā haʻawina Mīkini.

+Heluhelu Hana Kiʻekiʻe (HPC):Kākoʻo i ka koi ʻana i nā pono pūnaewele ma nā kaiapuni HPC, ka hoʻopili ʻana i nā mea InfiniBand a i ʻole Ethernet no ka helu ʻikepili nui.

+Nā Pūnaewele Ethernet a me InfiniBand:He mea maʻalahi kēia transceiver, e kākoʻo ana i ka 800G Ethernet (ma muli o IEEE P802.3ck) a me InfiniBand (e like me NVIDIA Quantum-2).

Palapala noi

  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou