800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Dual MPO-12/APC SMF Fiber Optical Transceiver Module
Wehewehena
+ ʻO ka noi transceiver fiber optic KCO-OSFP-800G-DR8 no ka transceiver OSFP e hoʻolako i ka pilina wikiwiki loa, haʻahaʻa-latency i nā kikowaena ʻikepili a me nā wahi High-Performance Computing (HPC), e hiki ai i nā pilina 800 Gigabit Ethernet (800GE) a me InfiniBand NDR (Next-gen Data Rate) a hiki i 500 mika ma ka fiber mode hoʻokahi.
+Kākoʻo nā transceivers fiber optic KCO-OSFP-800G-DR8 i nā pilina breakout no nā loulou 2x400G, 4x200G, a i ʻole 8x100G a kūpono me nā polokalamu e like me nā kuapo NVIDIA, nā adapters ConnectX-7, a me BlueField-3 DPU.
+Ua hoʻolālā ʻia ka module transceiver optical KCO-OSFP-800G-DR8 no ka throughput Ethernet 800GBASE a hiki i ka 500m mau lōʻihi loulou ma luna o ka OS2 single-mode fiber (SMF) me ka hoʻohana ʻana i kahi nalu o 1310nm ma o nā mea hoʻohui MTP/MPO-12 APC pālua.
+Ua kūlike kēia mea hoʻololi fiber optic KCO-OSFP-800G-DR8 me nā kūlana IEEE 802.3ck, IEEE 802.3cu a me OSFP MSA. ʻO ka nānā ʻana i nā diagnostics kikohoʻe (DDM) i kūkulu ʻia e ʻae i ke komo ʻana i nā palena hana manawa maoli.
+Hoʻohana ʻia kēia mea hoʻololi luna ʻili KCO-OSFP-800G-DR8 OSFP māhoe-awa i nā kuapo Ethernet i hoʻomaʻalili ʻia e ka ea.
+ Hōʻike ʻia me ka latency haʻahaʻa, ka mana haʻahaʻa, a me ka hilinaʻi, hiki iā ia ke hoʻopili i luna i nā hoʻolālā spine-leaf no nā noi kuapo-a-kuʻi, i lalo no nā loulou kuapo luna-o-rack i nā mea hoʻololi pūnaewele Ethernet, a/a i ʻole i nā BlueField-3 DPU i nā kikowaena compute a me nā ʻōnaehana mālama. ʻO ia ka hopena kūpono no ka helu ʻana HPC, AI, a me nā kikowaena ʻikepili ao.
Nā kikoʻī
| P/N | OSFP-800G-DR8-SM1310 |
| Inoa o ka Mea Kūʻai Aku | KCO |
| Kumu ʻAno | Luna Finned OSFP lua-awa |
| Ka wikiwiki o ka ʻikepili kiʻekiʻe loa | 850Gbps (8x 106.25Gbps) |
| Ka lōʻihi o ka nalu | 1310nm |
| Ka mamao o ke kaulahao kiʻekiʻe loa | 500m |
| Mea hoʻohuiʻano | ʻElua MTP/MPO-12 APC |
| ʻAno olonā | SMF |
| ʻAno Hoʻoili | EML |
| ʻAno Mea Hoʻokipa | PIN |
| Mana TX | -2.9~4.0dBm |
| Mana Loaʻa Haʻahaʻa Loa | -5.9dBm |
| Waihona Mana | 3dB |
| Ka nui o ka mea hoʻokipa | 4dBm |
| Ka hoʻohana ʻana i ka mana kiʻekiʻe loa | 16.5W |
| Lākiō o ka make ʻana | >3.5dB |
| Hoʻololi (Uila) | 8x100G-PAM4 |
| Hoʻololi (ʻIke) | Pālua 4x100G-PAM4 |
| ʻenehana hoʻopili | ʻŌpala COB (Chip on Board) |
| ʻAno Hoʻololi | PAM4 |
| CDR (Hoʻōla Uaki a me ka ʻIkepili) | TX & RX DSP i kūkulu ʻia |
| FEC i kūkulu ʻia | No |
| Nā Kūlana | OSFP MSA HW Rev 4.1, CMIS Rev 5.0, IEEE 802.3cu-2021, IEEE P802.3ck D2.2 |
| Palapala hoʻokō | 5 Makahiki |
Nā noi a me nā pono
+ Nā Kikowaena ʻIkepili Hana Kiʻekiʻe:Hāʻawi ka module KCO-OSFP-800G-DR8 i ka bandwidth e pono ai no ka hoʻopili ʻana i nā kuapo, nā kikowaena, a me nā ʻōnaehana pūnaewele ʻē aʻe i loko o nā kikowaena ʻikepili nui e kākoʻo i ka helu ao a me ka hoʻoili ʻikepili nui.
+ Kamepiula Hana Kiʻekiʻe (HPC):Pono nā hui HPC i nā wikiwiki hoʻoili ʻikepili nui no nā helu nui. Hoʻomaʻamaʻa ka KCO-OSFP-800G-DR8 i kēia mau pilina no nā supercomputers a me nā ʻōnaehana HPC ʻē aʻe.
+ Ethernet a me InfiniBand:Kākoʻo ia i nā protocols Ethernet a me InfiniBand, e hāʻawi ana i ka versatility no nā pono pūnaewele like ʻole i loko o ke kikowaena ʻikepili.
+ Nā hiki ke hoʻopau maʻalahi:ʻO ke kūlana KCO-OSFP-800G-DR8 o DR8 e ʻae i ka module e hana ma ke ʻano he loulou 800G hoʻokahi a i ʻole e "haʻihaʻi ʻia" i nā loulou wikiwiki haʻahaʻa he nui (2x400G, 4x200G, a i ʻole 8x100G), e hoʻopili ana i nā polokalamu like ʻole e like me NIC a i ʻole DPU.
+ʻO ke kaula uila no ke ʻano hoʻokahi (SMF):Me ka hoʻohana ʻana i ka fiber mode hoʻokahi, kākoʻo ke kūlana DR8 i nā pilina a hiki i 500 mika, e hāʻawi ana i ka pilina paʻa ma luna o nā mamao lōʻihi i loko o kahi hale.




