MTP-24 24fo Optical Fiber Elite Type Ultra Low Loss MTP/APC MPO/APC SM G657A1 Uea Kumu

Wehewehe Pōkole:

- Koho i ka ʻaoʻao huki

- Hoʻohui hoʻopau: MTP-12, MPO-12, MTP-24, MPO-24

- ʻAno hopena-maka: APC

- IL: Elite 0.35dB, ʻAno maʻamau: 0.65dB

- RL: 65dB

- ʻAhahui mua ʻia e ka hale hana.

- 100% hoʻāʻo ʻia ma mua o ka hoʻouna ʻana.

- ʻAʻahu uwea: LSZH, Melemele

- Ke ʻano fiber: ʻO ke ʻano hoʻokahi YOFC G657A1

- Ka lōʻihi o ke kaula kumu: i hoʻopilikino ʻia

- Lawelawe paʻi a me ka lepili uwea: ʻae.

- Hoʻopili ʻana: Pahu Kāleka Pahu Maʻamau me nā māka.


  • Kumukūʻai FOB:US $0.5 - 9,999 / ʻĀpana
  • Ka nui o ke kauoha liʻiliʻi loa:100 ʻāpana/ʻāpana
  • Ka hiki ke hoʻolako:10000 ʻāpana/ʻāpana i kēlā me kēia mahina
  • Nā kikoʻī huahana

    Nā Lepili Huahana

    He aha ka mea hoʻohui MPO APC?

    + ʻO nā mea hoʻohui MPO APC (Angled Physical Contact) he mau mea hoʻohui multi-fiber kiʻekiʻe-density e hōʻike ana i kahi pūnaewele multimode hoʻokahi-ʻano a me kekahi mau pūnaewele multimode hana kiʻekiʻe.

    + ʻO ka maʻamau, aia he 8, 12, 16, 24, 36 a i ʻole 48 mau olonā i loko o hoʻokahi mea hoʻohui, he mea nui lākou no nā kikowaena ʻikepili e koi ana i ka pohō hoʻokomo haʻahaʻa a me ka pohō hoʻihoʻi kiʻekiʻe.

    + Hōʻoia ka kihi 8 kekelē i nā leaka kukui i hoʻihoʻi ʻia i loko o ka uhi ʻana, e hāʻawi ana i ka pohō hoʻihoʻi maikaʻi loa i hoʻohālikelike ʻia me nā mea hoʻohui UPC (Ultra Physical Contact).

    + ʻO ka maʻamau, he ʻōmaʻomaʻo ke kala o nā mea hoʻohui APC.

    + No nā noi hana kiʻekiʻe, hoʻohana nui ʻia nā mea hoʻopili pili kino angled i nā ʻōnaehana mode hoʻokahi e pale aku i ka hana maikaʻi ʻole.

    KCO MPO APC

    E pili ana i ke kaula kumu MPO ʻano hoʻokahi

    + Hoʻohana ka uwea kumu hoʻokahi ʻano MPO APC i ka fiber Single Mode G657A1.

    + Waihoʻoluʻu ʻaʻahu uwea: hoʻohana maʻamau i ke kala melemele, ʻae ʻia e like me ke noi a ka mea kūʻai aku.

    + MPO APC Connector me ke kala ʻōmaʻomaʻo a me ka ʻaoʻao hope ferrule me 8 kekelē.

    E pili ana i nā kaula ʻano hoʻokahi

    + He ʻano liʻiliʻi ko ke kaula fiber optic ʻano hoʻokahi e hiki ai i hoʻokahi ʻano kukui ke hoʻolaha. Ma muli o kēia, emi ka nui o nā ʻōlinolino kukui i hana ʻia i ka wā e hele ai ke kukui ma o ke kumu, e hoʻohaʻahaʻa ana i ka attenuation a hana i ka hiki no ka hōʻailona ke hele hou aku. Hoʻohana pinepine ʻia kēia noi ma kahi mamao loa, bandwidth kiʻekiʻe e holo ʻia e Telcos, nā hui CATV, a me nā Koleke a me nā Kulanui.

    Nā noi

    + Hoʻohui kikowaena ʻikepili

    + Hoʻopau ʻana i ka hopena poʻo i kahi "iwi kuamoʻo" o ka fiber

    + Hoʻopau ʻana i nā ʻōnaehana rack fiber

    + Metro

    + Hoʻohui Kūʻē ʻo High-Density

    + Nā Pūnaewele Kelepona

    + Pūnaewele laulā/CATV//LAN/WAN

    + Nā Keʻena Hoʻāʻo

    Nā kikoʻī

    ʻAno

    ʻAno Hoʻokahi

    ʻAno Hoʻokahi

    ʻAno Multi

    (APC Polani)

    (UPC Polani)

    (PC Polani)

    Helu o ka fiber

    8, 12, 24 a pēlā aku.

    8, 12, 24 a pēlā aku.

    8, 12, 24 a pēlā aku.

    ʻAno Fiber

    G652D, G657A1 a pēlā aku.

    G652D, G657A1 a pēlā aku.

    OM1, OM2, OM3, OM4, OM5, a pēlā aku.

    Pohō Hoʻokomo Nui Loa

    ʻElite

    Kūlana Maʻamau

    ʻElite

    Kūlana Maʻamau

    ʻElite

    Kūlana Maʻamau

    Pohō haʻahaʻa

    Pohō haʻahaʻa

    Pohō haʻahaʻa

    0.35 dB

    0.75dB

    0.35 dB

    0.75dB

    0.35 dB

    0.60dB

    Hoʻihoʻi Pohō

    60 dB

    60 dB

    NA

    Ka paʻa

    500 mau manawa

    500 mau manawa

    500 mau manawa

    Mahana Hana

    -40~+80

    -40~+80

    -40~+80

    Ka lōʻihi o ka nalu hoʻāʻo

    1310nm

    1310nm

    1310nm

    Hoʻāʻo hoʻokomo-huki

    1000 mau manawa0.5 dB

    Hoʻololi

    0.5 dB

    Ka ikaika anti-tensile

    15kgf