ʻAoʻao hae

1 × 8 1 * 8 1: 8 ʻano pahu liʻiliʻi PLC fiber optic splitter

ʻO ka wehewehe pōkole:

• Haʻahaʻa hoʻokomo poho, kiʻekiʻe hoʻihoʻi poho

• Paʻa wela maikaʻi

• Ka hoʻihoʻi hou a me ka hoʻololi

• ʻO ka hoʻomanawanui mechanical maikaʻi loa

• Ka hoomalu ana i ka manawa hoola a me ka wela

• Nā kūlana ho'āʻo koʻikoʻi a me nā ala no ka maikaʻi

• Palekana kaiapuni (RoHS Compliance)

• Hiki ke hoʻopilikino ʻia ke kaula fiber optical patch e like me nā koi kikoʻī o nā mea kūʻai aku (Customized Connector / Length / package…)


Huahana Huahana

Huahana Huahana

Hōʻike huahana:

Hoʻokumu ʻia ka PLC fiber optic splitter ma ka planar Lightwave circuit circuit a me ke kaʻina hana pololei, hiki ke hoʻokaʻawale i hoʻokahi / pālua optical input (s) i loko o nā huahana optical he nui like ʻole a kapa ʻia ʻo 1 * N a i ʻole 2 * N.

ʻO ka PLC fiber optic splitter kahi ʻano o ka mana hoʻokele mana optical i hana ʻia me ka hoʻohana ʻana i ka ʻenehana ʻenehana optical waveguide.

Hōʻike ia i ka liʻiliʻi liʻiliʻi, hilinaʻi kiʻekiʻe, ākea ka lōʻihi o ka hawewe hana a me ka hoʻohui like ʻana o ke kahawai-a-kanal, a hoʻohana nui ʻia i nā pūnaewele PON e ʻike i ka hoʻokaʻawale ʻana i ka mana hōʻailona optical.

Hāʻawi ka PLC fiber optic splitter i ka hana optical kiʻekiʻe, ke kūpaʻa kiʻekiʻe a me ka hilinaʻi kiʻekiʻe, e hoʻokō i nā koi noi like ʻole i nā kaiapuni like ʻole.

1x8 PLC fiber optic splitter hele mai me 1 komo a me 8 puka. Hiki ke 0.6m, 1.0m, 1.5m ka lōʻihi o ke kaula komo a me ka hoʻopuka. Loaʻa ia me nā ʻano mea hoʻohui he nui e like me: SC/UPC, SC/APC, LC/UPC, LC/APC,

Hoʻohana nui ʻia ka 1x8 PLC fiber optic splitter ma 8 ports rack mount box for distriution frame, a i ʻole ākea hoʻohana ʻia ma 8 ports out fiber optic distribution box.

Noi:

Nā pūnaewele FTTX

Nā pūnaewele PON

Nā loulou CATV

Kūkākūkā ʻikepili

Ke kelepona

Hoʻokaʻawale i ka hōʻailona Optical

Hiʻona:

Haʻahaʻa hoʻokomo poho, kiʻekiʻe hoʻi poho

Paʻa wela maikaʻi

Hiki ke hoʻihoʻi hou a me ka hoʻololi

ʻO ka hoʻomanawanui mechanical maikaʻi loa

ʻO ka mālama ʻana i ka manawa mālama a me ka mahana

Nā kūlana ho'āʻo koʻikoʻi a me nā ala no ka maikaʻi

Palekana kaiapuni (RoHS Compliance)

Hiki ke hoʻopilikino ʻia ke kaula fiber optical patch e like me nā koi kikoʻī o nā mea kūʻai aku (Customized Connector/Length/pack...)

ka palena:

Hoʻonohonoho awa 1*8
Nalo hookomo (dB) Max 10.6
Kaulike nalo (dB) 1.0
PDL(dB) 0.25
Nalo pili i ka lōʻihi nalu (dB) 0.3
Temp. Pohō hilinaʻi (-40~85 ) (dB) 0.4

'Ōlelo Aʻo: No ka mea hoʻokaʻawale ʻole ka mea hoʻohui i luna.

Hoʻonohonoho awa 1*8
Nalo hookomo (dB) Max 10.8
Kaulike nalo (dB) 1.0
PDL(dB) 0.2
Nalo hilinaʻi ka lōʻihi nalu (dB) 0.3
Temp. Ke poho pili (-40~85°C ) (dB) 0.4

'Ōlelo Aʻo: ʻO ka palena ma luna nei no ka mea hoʻokaʻawale me ka mea hoʻohui.

Nā helu kiʻekiʻe loa

ʻĀpana

hōʻailona

Min.

Maʻamau

Max.

Unite

Ka Mahana Waihona

TS

-40

 

+85

°C

Ka Mahana Hana Hana SFP+ -10G-LR

TA

0

 

70

°C

SFP+ -10G-LR-I

-40

 

+85

°C

Kiekie Hoolako Voltage

Vcc

-0.5

 

4

V

Haʻahaʻa pili

RH

0

 

85

%

ʻAno Uila (TOP = 0 a 70 °C, VCC = 3.135 a 3.465 Volts)

ʻĀpana

hōʻailona

Min.

Maʻamau

Max.

Unite

Nānā

Voltage Hoolako

Vcc

3.135

 

3.465

V

 

Hāʻawi i kēia manawa

Icc

 

 

430

mA

 

Hoʻohana mana

P

 

 

1.5

W

 

Māhele hoʻouna:
Hoʻokomo ʻokoʻa impedance

Rin

 

100

 

Ω

1

Hoʻokomo ʻo Tx hoʻokahi i hoʻopau ʻia i ka ʻoluʻolu o ka uila DC (Ref VeeT)

V

-0.3

 

4

V

 

ʻOkoʻa ka hoʻokomo puʻe uila

Vin,pp

180

 

700

mV

2

Hoʻouna i ka Voltage Disable

VD

2

 

Vcc

V

3

Hoʻouna i ka Voltage Hiki

VEN

ʻO Vee

 

Vee+0.8

V

 

ʻĀpana mea loaʻa:
Hoʻokahi hoʻopau ʻana i ka Voltage Voltage

V

-0.3

 

4

V

 

ʻO Rx Output Diff Voltage

Vo

300

 

850

mV

 

ʻO Rx Output Piʻi a hāʻule manawa

Tr/Tf

30

 

 

ps

4

LOS hewa

VLOS hewa

2

 

VccHOME

V

5

LOS maʻamau

VLOS maʻamau

ʻO Vee

 

Vee+0.8

V

5

Nā memo:1. Hoʻopili pololei ʻia i nā pine hoʻokomo ʻikepili TX. Hoʻohui ʻia ʻo AC mai nā pine i ka IC mea hoʻokele laser.
2. No SFF-8431 Rev 3.0.
3. I loko o 100 ohms hoopau okoa.
4. 20%~80%.
5. ʻO LOS kahi puka hōʻiliʻili wehe. Pono e huki ʻia me 4.7k - 10kΩ ma ka papa hoʻokipa. ʻO ka hana maʻamau ka logic 0; ʻO ka nalowale o ka hōʻailona he logic 1. ʻO 5.5V ka mana huki huki kiʻekiʻe.

Nā ʻāpana Optical (TOP = 0 a 70°C, VCC = 3.135 a 3.465 Volts)

ʻĀpana

hōʻailona

Min.

Maʻamau

Max.

Unite

Nānā

Māhele hoʻouna:
Loʻihi nalu waena

λt

1290

1310

1330

nm

 

laula laula

λ

 

 

1

nm

 

Mana Optical Awelika

Pavg

-6

 

0

dBm

1

Mana OMA

Poma

-5.2

 

 

dBm

 

Mana Hoʻopau Laser

Poff

 

 

-30

dBm

 

Laki hoopau

ER

3.5

 

 

dB

 

Hoʻopaʻi hoʻopaʻi hoʻopuehu

TDP

 

 

3.2

dB

2

Halau Pilikino Pili

ʻO Rin

 

 

-128

dB/Hz

3

Optical Return Loss Tolerance

 

20

 

 

dB

 

ʻĀpana mea loaʻa:
Loʻihi nalu waena

λr

1260

 

1355

nm

 

Hoʻonaʻauao Mea Loaʻa

Ua haʻi aku ʻo Sen

 

 

-14.5

dBm

4

ʻO ka Manaʻo Koʻikoʻi (OMA)

Ua haʻi aku ʻo SenST

 

 

-10.3

dBm

4

Los Assert

LOSA

-25

 

-

dBm

 

Los Dessert

LOSD

 

 

-15

dBm

 

Los Hysteresis

LOSH

0.5

 

 

dB

 

ʻOi aku ka ukana

Sat

0

 

 

dBm

5

Hoʻomanaʻo Mea Loaʻa

Rrx

 

 

-12

dB

 

Nā memo:1. He ʻike wale nō nā helu mana maʻamau, no IEEE802.3ae.
2. Pono ka helu TWDP i ka papa hoʻokipa e hoʻokō SFF-8431. Ua helu ʻia ʻo TWDP me ka helu Matlab i hāʻawi ʻia ma ka paukū 68.6.6.2 o IEEE802.3ae.
3. 12dB noonoo.
4. Nā kūlana o nā ho'āʻo hoʻokipa koʻikoʻi ma IEEE802.3ae. Pono ka ho'āʻo CSRS i ka papa hoʻokipa e hoʻokō i ka SFF-8431.
5. ʻO ke kaumaha o ka mea hoʻokipa i ʻōlelo ʻia ma OMA a ma lalo o ke kūlana koʻikoʻi koʻikoʻi.

Nā ʻano manawa

ʻĀpana

hōʻailona

Min.

Maʻamau

Max.

Unite

TX_Hoʻopau i ka Manawa Manaʻo

hoopau

 

 

10

us

TX_Hoʻopau i ka manawa hōʻole

t_on

 

 

1

ms

ʻO ka manawa e hoʻomaka ai e hoʻokomo hou i TX_FAULT

t_int

 

 

300

ms

TX_FAULT mai Fault to Assertion

t_hewa

 

 

100

us

TX_Disable ka manawa e hoʻomaka ai e hoʻoponopono

t_reset

10

 

 

us

Nalo ka Manawa Hoailona Hoailona

TA,RX_LOS

 

 

100

us

Nalo ka Mea Loaʻa i ka manawa Deassert hōʻailona

Td,RX_LOS

 

 

100

us

Uku-koho i ka manawa hoʻololi

t_rateel

 

 

10

us

Manawa Uka ID Serial

t_serial-clock

 

 

100

kHz

Hoʻohana Pin

Diagram of Host Board Connector Block Pin Numbers and Name

huahana3

Nā wehewehe hana Pin

PIN

inoa

Hana

Nā memo

1

VeeT Ka honua transmitter module

1

2

Tx hewa ʻO ka hewa o ka transmitter module

2

3

Tx Hoʻopau Hoʻopau ka mea hoʻouna; Hoʻopau i ka hoʻopuka laser transmitter

3

4

SDL 2 uea uea serial interface hoʻokomo/puka (SDA)

 

5

SCL 2 uea serial interface clock input (SCL)

 

6

MOD-ABS ʻAʻohe Module, hoʻohui iā VeeR a i ʻole VeeT i ka module

2

7

RS0 E koho koho 0, e hoʻomalu i ka mea hoʻokipa SFP+. Ke kiʻekiʻe, hoʻokomo i ka helu ʻikepili >4.5Gb/s; inā haʻahaʻa, hoʻokomo i ka helu ʻikepili <=4.5Gb/s

 

8

LOS Nalo o ka hoailona o ka mea loaa

4

9

RS1 E koho koho 0, e hoʻomalu i ka SFP+ transmitter. Ke kiʻekiʻe, hoʻokomo i ka helu ʻikepili> 4.5Gb/s; inā haʻahaʻa, hoʻokomo i ka helu ʻikepili <=4.5Gb/s

 

10

VeeR ʻĀina hoʻokipa Module

1

11

VeeR ʻĀina hoʻokipa Module

1

12

RD- Ua hoʻohuli ʻia ka ʻikepili i waho

 

13

RD+ Loaʻa i ka ʻikepili i hoʻohuli ʻole ʻia i waho

 

14

VeeR ʻĀina hoʻokipa Module

1

15

VccR Hāʻawi ʻia ka module 3.3V

 

16

VccT Hāʻawi ka mea hoʻouna module 3.3V

 

17

VeeT Ka honua transmitter module

1

18

TD+ Mea hoʻouna i ka ʻikepili hoʻohuli i waho

 

19

TD- E hoʻouna i ka ʻikepili i hoʻohuli ʻole ʻia i waho

 

20

VeeT Ka honua transmitter module

1

Nānā:1. E hoʻokaʻawale ʻia nā pine lepo module mai ka pahu module.
2. ʻO kēia pine he pine hōʻiliʻili hāmama a huki ʻia me 4.7K-10Kohms iā Host_Vcc ma ka papa hoʻokipa.
3. E huki ʻia kēia pine me 4.7K-10Kohms i VccT i loko o ka module.
4. ʻO kēia pine he pine hōʻiliʻili wehe/hoʻoheheʻe ʻia a huki ʻia me 4.7K-10Kohms iā Host_Vcc ma ka papa hoʻokipa.

SFP Module EEPROM ʻIke a hoʻokele

Hoʻokomo nā modula SFP i ka protocol communication serial 2-wire e like me ka wehewehe ʻana ma ka SFP -8472. Hiki ke kiʻi ʻia ka ʻike ID serial o nā modula SFP a me nā ʻāpana Digital Diagnostic Monitor ma o ka I2C interface ma kahi helu A0h a me A2h. Kuhi ʻia ka hoʻomanaʻo ma ka Papa 1. Hōʻike ʻia ka ʻike ID kikoʻī (A0h) ma ka Papa 2, a me the DDM kiko'ī ma ka helu wahi A2h. No nā kikoʻī hou aku o ka palapala hoʻomanaʻo a me nā wehewehe byte, e ʻoluʻolu e nānā i ka SFF-8472, "Digital Diagnostic Monitoring Interface for Optical Transceivers". Ua hoʻopili ʻia nā ʻāpana DDM i loko.

Papakaukau1. Kikokikona Diagnostic Memory Map (Specific Data Field Description).

huahana1

Papa 2- EEPROM Serial ID Memory Contents (A0h)

Helu helu

Ka lōʻihi

(Byte)

Ka inoa o

Ka lōʻihi

ʻO ka wehewehe a me nā mea i loko

Nā kahua ID kumu

0

1

Mea hōʻike

ʻAno o ka mea hoʻolele kelepona (03h=SFP)

1

1

Mālama ʻia

ʻIke lōʻihi o ke ʻano transceiver serial (04h)

2

1

Mea hoʻohui

Code o ke ʻano hoʻohui opi (07=LC)

3-10

8

Mea lawe lawe

10G Base-LR

11

1

Hoʻopili

64B/66B

12

1

BR, Nominal

Nominal baud rate, unit of 100Mbps

13-14

2

Mālama ʻia

(0000h)

15

1

Ka lōʻihi(9um)

Kākoʻo ʻia ka lōʻihi o ka loulou no ka fiber 9/125um, nā ʻāpana o 100m

16

1

Ka lōʻihi (50um)

Kākoʻo ʻia ka lōʻihi o ka loulou no ka fiber 50/125um, nā ʻāpana o 10m

17

1

Ka lōʻihi (62.5um)

Kākoʻo ʻia ka lōʻihi o ka loulou no ka fiber 62.5/125um, nā ʻāpana o 10m

18

1

Length(Copper)

Kākoʻo ʻia ka lōʻihi o ka loulou no ke keleawe, nā ʻāpana mika

19

1

Mālama ʻia

 

20-35

16

Ka inoa o ka mea kuai

SFP inoa mea kūʻai:VIP Fiber

36

1

Mālama ʻia

 

37-39

3

Mea kūʻai OUI

SFP transceiver mea kūʻai aku OUI ID

40-55

16

Mea kūʻai PN

Helu Mahele: “SFP+ -10G-LR” (ASCII)

56-59

4

ʻO ka mea kūʻai aku rev

Ka pae hoʻoponopono no ka helu ʻāpana

60-62

3

Mālama ʻia

 

63

1

CCID

Paita liʻiliʻi liʻiliʻi o ka huina ʻikepili ma ka helu wahi 0-62
Nā kahua ID i hoʻonui ʻia

64-65

2

Koho

Hōʻike i nā hōʻailona SFP optical i hoʻokō ʻia

(001Ah = LOS, TX_FAULT, TX_DISABLE i kākoʻo ʻia)

66

1

BR, ka nui

ʻO ka palena ʻuʻuku o luna, nā ʻāpana o %

67

1

BR, min

ʻO ka palena ʻāpana liʻiliʻi haʻahaʻa, nā ʻāpana o %

68-83

16

Mea kūʻai aku ʻo SN

Helu helu (ASCII)

84-91

8

Code lā

VIP Fiber's Manufacturing date code

92-94

3

Mālama ʻia

 

95

1

CCEX

E nānā i ke code no nā kahua ID i hoʻonui ʻia (nā helu 64 a i 94)
Nā kahua ID kikoʻī o ka mea kūʻai aku

96-127

32

Hiki ke heluhelu

VIP Fiberlā kikoʻī, heluhelu wale nō

128-255

128

Mālama ʻia

Mālama ʻia no SFF-8079

Nā hiʻohiʻona kikohoʻe kikohoʻe

Helu helu

ʻĀpana

Ka pololei

Unite

96-97 Ka Wela Kuloko ±3.0 °C
100-101 ʻO ke ʻano ʻo Laser Bias i kēia manawa ±10 %
100-101 Tx Puka Mana ±3.0 dBm
100-101 Mana Hookomo Rx ±3.0 dBm
100-101 VCC3 Voltage Hoolako Kuloko ±3.0 %

Hoʻokō hoʻoponopono

ʻO kaSFP+ -10G-LR me ka International Electromagnetic Compatibility (EMC) a me nā koi a me nā kūlana palekana honua (e ʻike i nā kikoʻī ma ka papa ma hope).

Hoʻokuʻu Electrostatic

(ESD) i na Pin Uila

MIL-STD-883E

Hana 3015.7

Papa 1(>1000 V)
Hoʻokuʻu Electrostatic (ESD)

i ka Duplex LC Receptacle

IEC 61000-4-2

GR-1089-CORE

Kūlike me nā kūlana
Electromagnetic

Hoʻopilikia (EMI)

FCC Māhele 15 Papa B

EN55022 Papa B (CISPR 22B)

VCCI Papa B

Kūlike me nā kūlana
Palekana Maka Maka FDA 21CFR 1040.10 a me 1040.11

EN60950, EN (IEC) 60825-1,2

E kūpono me ka papa 1 laser

huahana.

Kaapuni Manao

huahana4

Manaʻo ʻia ʻo Host Board Kaapuni Mana

huahana5

Manaʻo ʻia ʻo High-speed Interface Circuit

ʻIkepili ʻenehana:

Ka lōʻihi o ka fiber 1.0ma i ʻole i hoʻopilikino ʻia
ʻAno hoʻohui SC,LC,

FC

a i ʻole i hoʻopilikino ʻia

ʻAno Optical Fiber G652DG657A1

a i ʻole i hoʻopilikino ʻia

Kuhikuhi (dB) Min * 55
Pohō (dB) Min * 55 (50)
Ka Mana Mana (mW) 300
Loʻihi hawewe hana (nm) 1260 ~ 1650
Ka Mahana Hana (°C) -40 ~ +85
Mahana Waihona (°C) -40 ~ +85

Laina hana:

huahana_1

  • Mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou